ENERGY EFFICIENCY OF HEAT PUMPING STATIONS WITH DIFFERENT HEAT SOURCES ON CONDITION OF VARIABLE OPERATION MODES

Authors

  • Olga Ostapenko Vinnytsia National Technical University
  • Olga Shevchenko LLC “Scientific Production Association TEPLOENERGORESURS”
  • Olena Bakum Vinnytsia National Technical University

Keywords:

energy efficiency, heat pumping station, heat pumping, installation, operation mode of heat supply systems

Abstract

The paper determines modes of efficient operation of heat pumping stations (HPS) with different types of compressor drive and sources of low-temperature heat on condition of variable operation modes of heat supply systems. The suggested recommendations make it possible to choose HPS and low-temperature sources operation modes in order to achieve the desired values of efficiency indices for HPS year-round operation. The suggested recommendations can be used for the forecast of rational operation modes of HPS of various capacity in heat supply systems.

Author Biographies

Olga Ostapenko, Vinnytsia National Technical University

Cand. Sc. (Eng.), Assistant Professor, Department of Power Engineering

Olga Shevchenko, LLC “Scientific Production Association TEPLOENERGORESURS”

Administration manager

Olena Bakum, Vinnytsia National Technical University

Student, Institute of Civil Engineering, Power Engineering and Gas Supply

Downloads

Abstract views: 313

Published

2015-11-25

How to Cite

[1]
O. Ostapenko, O. Shevchenko, and O. Bakum, “ENERGY EFFICIENCY OF HEAT PUMPING STATIONS WITH DIFFERENT HEAT SOURCES ON CONDITION OF VARIABLE OPERATION MODES”, Works of VNTU, no. 4, Nov. 2015.

Issue

Section

Energetics and Electrical Engineering

Metrics

Downloads

Download data is not yet available.

Most read articles by the same author(s)

<< < 1 2